Replacement drain pump used for some Amana, Inglis, Kenmore, Maytag, and Whirlpool washer models.
Directly Replaces: W10730972, AP5958431, W10130913, 8540024, 8540025, 8540027, 8540028, 8540996, W10117829, W10183434, W10190647, W10190648, W10201457.
Features:
- Pumps water out of the tub through the drain hose.
- Pump motor with coin trap.
- Fits front load washers.
- Includes (1) complete drain pump and motor assembly with pump housing, and filter.
Specifications:
- Color: White / Gray / Black.
- Material: Plastic / Metal / Rubber.
- Electrical Specs: 120~V, 60Hz, 1.25A, CL.A.
- Run Time: 10min ON / 50 min OFF.
- Dimensions: Approx. 9-1/4"L x 6-3/4"W x 6-1/8"H.
Compatible Models:
Don't see your model listed? Submit this form to get help finding the right part.
The drain pump removes water out of the tub through the drain hose.
Failure Symptoms: When the drain pump fails you might experience poor or no drainage, or water leakage from the the unit.
How to Test: If you're experiencing water leakage, check the pump for cracks/damage that the water is leaking from. If the bearings are worn out they can possibly be the source of the leak, so check them as well. If the pump is the source of the leak, it should be replaced.
If you're experiencing poor or no drainage, check to make sure there is nothing clogging the pump. Sometimes small pieces of clothing can get caught in the pump, preventing proper drainage. If there is nothing obstructing the pump, but still noisy during the drain cycle, the pump could be defective and needs replaced.
Repair Tip: To prevent pump blockage, use a mesh laundry to wash small articles of clothing, such as socks.
Disclaimer: Information and recommendations contained herein are believed to be accurate as of the date hereof. Since the conditions and methods of use of the information referred to are beyond control, ApplianceRepairForum.com and Thrifty Appliance Parts LLC, cannot be held liable for results obtained or arising from use or reliance on such information.
The User assumes responsibility associated with making test measurements, adjustments, parts replacements and any other action necessary to perform any recommended procedures. It is the responsibility of the User to ask for clarification if a recommendation is not fully understood, including the risks and hazards associated with the recommended procedures.