Replacement thermal fuse & harness used for some Estate, Kenmore, KitchenAid, Maytag, and Whirlpool dishwasher models.

Directly Replaces: 675813, 3375557, 3376359, 675813VP, DW5813, 679723, AH382828, AP3115186, EA382828, EAP382828, PD00002439, PS382828.

Features:

  • Cuts off power to the dishwasher if the dishwasher overheats.
  • Includes (1) Thermal Cutoff Fuse with 2-Wire Harness, (1) Zip Tie, Instructions.

Specifications:

  • Color: White / Brown.
  • Material: Metal / Plastic.
  • Fuse Dimensions: 1-1/16"L x 1"W x 7/16"H.
  • Additional Dimensions: Lead extends approx. 18" from fuse.
  • View Instructions

Compatible Models:

How do I find my model number?
675813 Dishwasher Thermal Fuse & Harness For Kenmore

Repair Skill Level: 2 | Beginner to Moderate
Minimal disassembly (if any) and some basic tools may be needed.

Part Description: The thermal fuse cuts off power to the dishwasher if the dishwasher overheats.

Failure Symptoms: Dishwasher won't start.

Testing: Test for continuity with a multimeter. If there is no continuity, the fuse should be replaced.

Bonus Tip: The thermal fuse blows when the dishwasher overheats. If you're replacing the fuse, you should also look for what's causing your dishwasher to overheat and replace that item as well.

Disclaimer: Information and recommendations contained herein are believed to be accurate as of the date hereof. Since the conditions and methods of use of the information referred to are beyond control, ApplianceRepairForum.com and Thrifty Appliance Parts LLC, cannot be held liable for results obtained or arising from use or reliance on such information.
The User assumes responsibility associated with making test measurements, adjustments, parts replacements and any other action necessary to perform any recommended procedures. It is the responsibility of the User to ask for clarification if a recommendation is not fully understood, including the risks and hazards associated with the recommended procedures.