Replacement solenoid kit used for some Admiral, Amana, Crosley, Danby, Electrolux, Estate, Frigidaire, GE, Gibson, Hotpoint, Inglis, Jenn-Air, Kenmore, KitchenAid, Magic Chef, Maytag, RCA, Roper, Samsung, Speed Queen, Whirlpool, and White-Westinghouse dryer models.
Directly Replaces: 279834, 279834VP, 279834BULK, 694540, 694539, 12001349, 306105, 306106, 14202750, 14205025, 14210032, 14210725, 14210908, 14201336, 14201452, 3-6105, 3-6106, 303558, 306103, 58804A, 58804B, 63-6614, 63-6615, R0610003, R0610050, F91-3889, F91-3890, K35-288, K35-355, K35-450, SCA700, DE382, 5303931775 08015679, 08015680, 3201243, 3201244, 3281142, 3281143, 5300622602, 5303307291, 5303307292, 5308015680, 710, F140570-300, F140570-400, G140570-300, G140570-400, Q000622601, Q000622602, Q622601, Q622602, WQ622601, WQ622602, WE04X10020, WE4X692, WE04X0692, WE4X693, WE04X0693, WE04X0748, WE04X0749, WE04X10004, WE04X10031, WE04X10048, WE4X10004, WE4X10020, WE4X10031, WE4X10048, WE4X748, WE4X749, 3479, 3449, 276799, 276800, 771216, AH334310, AH265259, AH268153, AH268154, AP3094251, AP2150379, AP2042925, AP2042752, AP2042753, EAP470049, EA334310, EA265259, EA268153, EA268154, EAP268153, EAP268154, EAP265259, EAP334310, PD00002350, PD00000108, PD00001591, PD00008216, PD00009041, PS334310, PS470049, PS265259, PS268153, PS268154.
Features:
- Opens and closes the valve to control the flow of gas.
- Fits all dryers with standard "M" two-coil gas valves.
- Whenever one coil fails, both coils should be replaced.
- Includes (1) 2-Terminal Secondary Coil, (1) 3-Terminal Primary Boost/Hold Coil.
Specifications:
- Color: Black / White.
- Material: Plastic / Metal.
- 2-Terminal Solenoid Dimensions: 3-3/16"L x 2"W x 5/8"H.
- 3-Terminal Solenoid Dimensions: 1-3/8"L x 15/16"W x 1-1/8"H.
Compatible Models:
Don't see your model listed? Submit this form to get help finding the right part.
Repair Skill Level: 2 | Beginner to Moderate
Minimal disassembly (if any) and some basic tools may be needed.
Part Description: The coil pens and closes the valve to control the flow of gas.
Failure Symptoms: Dryer does not heat or heats intermittently.
Testing: Watch the burner and if the igniter glows for a while and then shuts off without the gas igniting, it usually means one of these coils is bad.
Bonus Tip: You can reduce wrinkles and dry time by shaking out your clothes before putting them into the dryer.
Disclaimer: Information and recommendations contained herein are believed to be accurate as of the date hereof. Since the conditions and methods of use of the information referred to are beyond control, ApplianceRepairForum.com and Thrifty Appliance Parts LLC, cannot be held liable for results obtained or arising from use or reliance on such information.
The User assumes responsibility associated with making test measurements, adjustments, parts replacements and any other action necessary to perform any recommended procedures. It is the responsibility of the User to ask for clarification if a recommendation is not fully understood, including the risks and hazards associated with the recommended procedures.