Replacement thermal fuse used for some LG and Kenmore dryer models.

Directly Replaces: 6931EL3003D, 6931EL3003E, L3003D, 1268366, AH3530485, AP4440975, EA3530485, EAP3530485, PD00001818, PS3530485.

Features:

  • Safety fuse that blows in order to cut off power if the dryer overheats.
  • Located on the heating element or housing.
  • Non-resettable thermal limiter.
  • Includes (1) Thermal Fuse.

Specifications:

  • Color: Gray / White.
  • Material: Porcelain / Metal.
  • Dimensions: 1-1/4"L x 1-1/8"W x 2-1/4"H.

Compatible Models:

How do I find my model number?
6931EL3003D Dryer Thermal Fuse For Kenmore

Repair Skill Level: 2 | Beginner to Moderate
Minimal disassembly (if any) and some basic tools may be needed.

Part Description: The Thermal fuse is a safety fuse that blows in order to cut off power if the dryer overheats.

Failure Symptoms: Dryer won't start; Dryer won't heat.

Testing: Use a multimeter to test it for continuity. If there is no continuity it should be replaced.

Bonus Tip: A blown thermal fuse indicates a restriction in the exhaust vent that runs from the dryer to the outside. Be sure to check the dryer venting whenever you need to replace the thermal fuse. Also check for build up on your lint filter screen. Residue from dryer sheets and fabric softener can build up on lint screens and restrict air flow.

Disclaimer: Information and recommendations contained herein are believed to be accurate as of the date hereof. Since the conditions and methods of use of the information referred to are beyond control, ApplianceRepairForum.com and Thrifty Appliance Parts LLC, cannot be held liable for results obtained or arising from use or reliance on such information.
The User assumes responsibility associated with making test measurements, adjustments, parts replacements and any other action necessary to perform any recommended procedures. It is the responsibility of the User to ask for clarification if a recommendation is not fully understood, including the risks and hazards associated with the recommended procedures.